Programming 24 hour programme with 2 ON/OFF operations per day
Display 24 hour dial
Mounting Surface mounting
Current Rating SPST: 20amp resistive
Supply 230V, 50/60 Hz a.c.
Base Type 4 Pin
Reserve 100 hrs (providing battery has been charged for 300 hrs)
Day Omission Yes (omits the “ON” operation)
Early Operation Yes (Early “ON”)
Temp Override Facility Advance to “OFF”, when program “ON” and will remain “OFF” unit next
(Manual Button) “ON” operation and vice versa
Cable Size 6.0mm2
Timing Accuracy 5 mins/year
Power Consumption 0.6W at 230V
Ambient Temperature Range Designed to operate over a temperature range of 0°C to 50°C continuous
Live Parts Protection This timer is totally protected by its enclosure
Dirt Protection Normal domestic dust deposits only
Moisture Protection Ordinary: has no special protection against moisture
Shock Protection Class 1 (Product must be earthed)
Dial Calibration 15 min divisions
Setting Accuracy +/- 3 minutes
Conforms to BS EN60730
Dimensions Height (wall mounted) 136mm, width 105.7mm, projection 82mm, (Total height 146.5mm)
1 – Live In (Clock & Load) – External link 1 to 3 if using a single 230Vac supply
2 – Live Out (Load 20A circuit – Lever A)
3 – Live Out (Load 10A circuit – Lever B)
4 – Neutrals
Earth Posn – Earth